Amphenol Advanced Sensors Sensori di gas
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Mostra filtri
Ripristina filtri
Applica filtri
CategoriaSensori / Sensori di gas / Sensori di gas
ProduttoreAmphenol Advanced Sensors
Record 43
Pagina 2/2
Immagine |
Numero parte |
Produttore |
Descrizione |
Disponibile |
Quantità |
Serie | Tipo | Gamma di ossigeno | Precisione | Uscita | Temperatura di esercizio | Tensione - Alimentazione | Corrente - Alimentazione |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Amphenol Advanced Sensors |
CO2 MOD 5000PPM DIFF W/GAS PORTS |
4.194 |
|
- | Carbon Dioxide (CO2) | - | ±5% | 0 V ~ 4 V | 0°C ~ 50°C | 5VDC | - |
|
|
Amphenol Advanced Sensors |
CO2 MODULE 5000PPM FLOW THROUGH |
5.310 |
|
- | Carbon Dioxide (CO2) | - | ±5% | 0 V ~ 4 V | 0°C ~ 50°C | 5VDC | - |
|
|
Amphenol Advanced Sensors |
CO2 MODULE 2000PPM DIFFUSION |
4.356 |
|
- | Carbon Dioxide (CO2) | - | 10% | 0 V ~ 4 V | 0°C ~ 50°C | 5VDC | - |
|
|
Amphenol Advanced Sensors |
CO2 TRANSMITTER INDUCT MOUNT 0-1 |
7.236 |
|
Ventostat® | Carbon Dioxide (CO2) | - | ±5% | 0 V ~ 10 V | 0°C ~ 50°C | 18V ~ 40V | 40mA |
|
|
Amphenol Advanced Sensors |
CO2 TRANSMITTER INDUCT MOUNT 0-5 |
5.094 |
|
Ventostat® | Carbon Dioxide (CO2) | - | ±5% | 0 V ~ 5 V | 0°C ~ 50°C | 18V ~ 40V | 40mA |
|
|
Amphenol Advanced Sensors |
CO2 TRANSMITTER INDUCT MOUNT 0-1 |
6.444 |
|
Ventostat® | Carbon Dioxide (CO2) | - | ±5% | 0 V ~ 10 V | 0°C ~ 50°C | 18V ~ 40V | 40mA |
|
|
Amphenol Advanced Sensors |
CO2 TRANSMITTER INDUCT MOUNT 0-5 |
7.668 |
|
Ventostat® | Carbon Dioxide (CO2) | - | ±5% | 0 V ~ 5 V | 0°C ~ 50°C | 18V ~ 40V | 40mA |
|
|
Amphenol Advanced Sensors |
CO2 SENSOR DUCT MOUNT 0-10V OUT |
6.534 |
|
- | Carbon Dioxide (CO2) | - | 3% | 0 V ~ 5 V, 0 V ~ 10 V (Selectable) | 0°C ~ 50°C | 18 VAC ~ 30VAC RMS, 18 VDC ~ 42 VDC | - |
|
|
Amphenol Advanced Sensors |
CO2/TEMP SENS WALL MNT DUAL OUT |
3.150 |
|
T8000 | Carbon Dioxide (CO2) | - | ±5% | 0 V ~ 5 V, 0 V ~ 10 V (Selectable) | 0°C ~ 50°C | 18 VAC ~ 30VAC RMS, 18 VDC ~ 42 VDC | 4 ~ 20mA |
|
|
Amphenol Advanced Sensors |
CO2/TEMP SENS DUCT MNT DUAL OUT |
4.212 |
|
T8000 | Carbon Dioxide (CO2) | - | ±5% | 0 V ~ 5 V, 0 V ~ 10 V (Selectable) | 0°C ~ 50°C | 18 VAC ~ 30VAC RMS, 18 VDC ~ 42 VDC | 4 ~ 20mA |
|
|
Amphenol Advanced Sensors |
SENSOR GAS FOR CO/NO2 EXHAUST |
8.874 |
|
- | CO, NO2 | - | - | - | -10°C ~ 55°C | 5V | - |
|
|
Amphenol Advanced Sensors |
CO2/TEMP SENSOR WALL MNT 0-10V |
2.466 |
|
T5000 | Carbon Dioxide (CO2) | - | 10% | 0 V ~ 10 V | 0°C ~ 50°C | 18 VAC ~ 32VAC RMS, 18 VDC ~ 42 VDC | - |
|
|
Amphenol Advanced Sensors |
CO2/TEMP SENSOR WALL MNT 0-10V |
7.974 |
|
T5000 | Carbon Dioxide (CO2) | - | 10% | 0 V ~ 10 V | 0°C ~ 50°C | 18 VAC ~ 32VAC RMS, 18 VDC ~ 42 VDC | - |