Record 42.170
Pagina 824/1406
Immagine |
Numero parte |
Produttore |
Descrizione |
Disponibile |
Quantità |
Serie | Tipo interruttore | Corrente nominale (Amp) | Tensione nominale - AC | Tensione nominale - CC | Numero di poli | Tipo di attuatore | Illuminazione | Tensione di illuminazione (nominale) | Tipo di montaggio | Approvazioni |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
E-T-A |
CIR BRK MAG-HYDR 6A 240VAC/80VDC |
6.984 |
|
8340-T | Magnetic (Hydraulic Delay) | 6A | 240V | 80V | 2 | Lever | None | - | DIN Rail | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489A |
|
![]() |
E-T-A |
CIR BRK MAG-HYDR 8A 240VAC/80VDC |
7.056 |
|
8340-T | Magnetic (Hydraulic Delay) | 8A | 240V | 80V | 2 | Lever | None | - | DIN Rail | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489A |
|
![]() |
E-T-A |
CIR BRK M-HYDR 20MA 240VAC/80VDC |
6.840 |
|
8340-T | Magnetic (Hydraulic Delay) | 20mA | 240V | 80V | 2 | Lever | None | - | DIN Rail | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489A |
|
![]() |
E-T-A |
CIR BRK MAG-H 100MA 240VAC/80VDC |
4.302 |
|
8340-T | Magnetic (Hydraulic Delay) | 100mA | 240V | 80V | 2 | Lever | None | - | DIN Rail | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489A |
|
![]() |
E-T-A |
CIR BRK MAG-H 250MA 240VAC/80VDC |
5.706 |
|
8340-T | Magnetic (Hydraulic Delay) | 250mA | 240V | 80V | 2 | Lever | None | - | DIN Rail | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489A |
|
![]() |
E-T-A |
CIR BRK MAG-H 500MA 240VAC/80VDC |
2.412 |
|
8340-T | Magnetic (Hydraulic Delay) | 500mA | 240V | 80V | 2 | Lever | None | - | DIN Rail | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489A |
|
![]() |
E-T-A |
CIR BRK MAG-HYD 10A 240VAC/80VDC |
8.982 |
|
8340-T | Magnetic (Hydraulic Delay) | 10A | 240V | 80V | 2 | Lever | None | - | DIN Rail | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489A |
|
![]() |
E-T-A |
CIR BRK MAG-HYD 12A 240VAC/80VDC |
6.750 |
|
8340-T | Magnetic (Hydraulic Delay) | 12A | 240V | 80V | 2 | Lever | None | - | DIN Rail | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489A |
|
![]() |
E-T-A |
CIR BRK MAG-HYD 15A 240VAC/80VDC |
4.320 |
|
8340-T | Magnetic (Hydraulic Delay) | 15A | 240V | 80V | 2 | Lever | None | - | DIN Rail | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489A |
|
![]() |
E-T-A |
CIR BRK MAG-HYD 16A 240VAC/80VDC |
3.204 |
|
8340-T | Magnetic (Hydraulic Delay) | 16A | 240V | 80V | 2 | Lever | None | - | DIN Rail | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489A |
|
![]() |
E-T-A |
CIR BRK MAG-HYDR 1A 240VAC/80VDC |
8.532 |
|
8340-T | Magnetic (Hydraulic Delay) | 1A | 240V | 80V | 2 | Lever | None | - | DIN Rail | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489A |
|
![]() |
E-T-A |
CIR BRK MAG-HYD 20A 240VAC/80VDC |
3.564 |
|
8340-T | Magnetic (Hydraulic Delay) | 20A | 240V | 80V | 2 | Lever | None | - | DIN Rail | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489A |
|
![]() |
E-T-A |
CIR BRK MAG-HYD 25A 240VAC/80VDC |
8.298 |
|
8340-T | Magnetic (Hydraulic Delay) | 25A | 240V | 80V | 2 | Lever | None | - | DIN Rail | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489A |
|
![]() |
E-T-A |
CIR BRK MAG-HYDR 2A 240VAC/80VDC |
7.002 |
|
8340-T | Magnetic (Hydraulic Delay) | 2A | 240V | 80V | 2 | Lever | None | - | DIN Rail | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489A |
|
![]() |
E-T-A |
CIR BRK MAG-HYD 30A 240VAC/80VDC |
6.480 |
|
8340-T | Magnetic (Hydraulic Delay) | 30A | 240V | 80V | 2 | Lever | None | - | DIN Rail | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489A |
|
![]() |
E-T-A |
CIR BRK MAG-HYDR 3A 240VAC/80VDC |
5.940 |
|
8340-T | Magnetic (Hydraulic Delay) | 3A | 240V | 80V | 2 | Lever | None | - | DIN Rail | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489A |
|
![]() |
E-T-A |
CIR BRK MAG-HYDR 5A 240VAC/80VDC |
8.676 |
|
8340-T | Magnetic (Hydraulic Delay) | 5A | 240V | 80V | 2 | Lever | None | - | DIN Rail | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489A |
|
![]() |
E-T-A |
CIR BRK MAG-HYDR 6A 240VAC/80VDC |
7.884 |
|
8340-T | Magnetic (Hydraulic Delay) | 6A | 240V | 80V | 2 | Lever | None | - | DIN Rail | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489A |
|
![]() |
E-T-A |
CIR BRK MAG-HYDR 8A 240VAC/80VDC |
3.960 |
|
8340-T | Magnetic (Hydraulic Delay) | 8A | 240V | 80V | 2 | Lever | None | - | DIN Rail | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489A |
|
![]() |
E-T-A |
CIRC BRKR THRM |
8.964 |
|
3130-F | Thermal | 2A | 250V | 50V | 2 | Rocker | Green | 185 ~ 275V | Panel Mount | - |
|
![]() |
E-T-A |
CIR BRKR MAG-HYDR 60A 80VDC |
3.600 |
|
8345 | Magnetic (Hydraulic Delay) | 60A | - | 80V | 1 | Lever | - | - | Panel Mount | CSA C22.2 No 235, GB 17701, IEC 60934, UL1077, UL489 |
|
![]() |
Sensata-Airpax |
CIRCUIT BREAKER MAG-HYDR LEVER |
6.912 |
|
* | - | - | - | - | - | - | - | - | - | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR |
3.546 |
|
- | - | - | - | - | - | - | - | - | - | - |
|
![]() |
E-T-A |
CIRC BRKR THRM |
7.974 |
|
3120-F | Thermal | 20A | 250V | 50V | 2 | Rocker | None | - | Panel Mount | - |
|
![]() |
E-T-A |
CIR BRKR THRM 30A |
3.474 |
|
413 | - | 30A | - | - | - | - | - | - | - | CSA C22.2 No 235, UL1077 |
|
![]() |
E-T-A |
CIR BRKR THRM 50A |
5.706 |
|
413 | - | 50A | - | - | - | - | - | - | - | CSA C22.2 No 235, UL1077 |
|
![]() |
E-T-A |
CIRC BRKR THRM |
5.940 |
|
3120-F | Thermal | 16A | 250V | 50V | 2 | Rocker | None | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR LEVER |
6.570 |
|
IUG | Magnetic (Hydraulic Delay) | - | - | - | 2 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR LEVER 15A |
4.950 |
|
IPA | Magnetic (Hydraulic Delay) | 15A | - | - | 3 | Lever | - | - | Panel Mount | - |
|
![]() |
E-T-A |
CIR BRKR THRMAG 20A 250VAC/75VDC |
2.952 |
|
2215 | Thermal Magnetic | 20A | 250V | 75V | 1 | Lever | - | - | Through Hole | CSA C22.2 No 235, UL1077 |